RITEC
Description
RITEC check valves prevent backflow of water and mitigate pressure surges through their gradual and controlled closing mechanism. Their axially-flowing, cast-body design minimizes pressure losses while ensuring maximum resistance to cavitation and noise. In addition to the standard model, AC and CP versions are available to further reduce cavitation phenomena.
Features
- Design pressure: up to 40 bar
- Maximum inlet pressure: up to 25 bar
- Maximum treated water temperature: 70°C
- Nominal sizes (DN): flanged version 50, 80, 100, 150, 200, 250, 300, 400, 500, 600
- Connections: PN 10, 16, 25 according to EN 1092-2 and Class 150 according to ASME B16.5